小金棋牌

  • 选择申克牌自动灌装机是您最佳的选择

联系方式

无锡申克自动化工程有限公司

地址:江苏无锡市新吴区江溪街道锡义路79号 
电话:0510-8211 7500
传真:0510-8529 8619 
手机:137 7157 0400(杜工),

      158 0619 1882(沈工)

邮箱:wxskzd@163.com
 





皮带秤称重仪表ICS-DT-6说明书(四)

来源: 日期:2017-02-24 19:21:47 点击:443 属于:行业新闻


77  附录 Appendix


7.1 本说明书对应的软件版本 This Manual Instructions are in corresponding to relevant software edition.

调速秤Timing Weigher: FC07.10PL

恒速秤Weigher of Constant Speed: FC07。10PH

l      订货时必须说明物料性质、容重、台时产量、输送方式、现场工艺布局等数据,以便于选型或特殊设计。When order, please note the nature of material, relative volume weight, shift production, transmission mode, site configuration and etc data, so as to be convenient for model selection.

l      上面文字或数值若有修改,一律以产品所附说明书为准。In case of amendment of the literature or value abovementioned, the Manual Instructions attached to the product prevails.

7.2  ICS-DT-6型控制仪与PLC控制协议(远程IO)  ICS-DT-6 control Instrument & PLC Control Protocol (Remote IO)

ICS-DT-6处于远程控制时:When ICS-DT-6 is at Remote Control mode:

7.2.1I/O信号Signal:

7.2.1.1 当控制仪上电就绪或无故障时,控制仪给出“备妥”信号。When the control instrument is energized and ready free of trouble, the control instrument shall issue “Ready” signal.

7.2.1.2 当PLC给出“外启动”信号,同时PLC给出“联锁”信号时,ICS-DT-6控制仪开始配料;当上述信号同时或任一个信号去掉时,控制仪停止配料。When the PLC issues the signal of “Exterior Start”, and at the same time, issues the signal of “Interlock”, the ICS-DT-6 Control Instrument starts material mixing; when abovementioned signals simultaneously or any one of the signals drops off, the control instrument stops material mixing.

7.2.1.3 当线载荷超限或长时间超限(3分钟)时,控制仪给出“故障”信号,去除“备妥”信号。When linear load exceeds limit or exceeds limit for a long period of time (3 minutes), the control instrument shall issue the signal of “Failure” and sign off the signal of “Ready”.

7.2.1.4 当控制仪报警消除后,控制仪去除“故障”信号,同时给出“备妥”信号。When the alarm signal from the control instrument is eliminated, the instrument shall issue signal of “Ready” instead of “Failure”.

7.2.1.5 控制仪处于运行状态时,控制仪给出“运行”信号;否则去除“运行”信号。When the control instrument is under running status, the control instrument shall issue signal of “Run”; or take off signal of “Run”.

7.2.1.6 上述所有的触点信号均为无源触点,闭合有效。 All the contact signals abovementioned are all passive contacts, valid when closed.

ICS-DT-6控制仪处于本地控制时,控制仪不受PLC控制。When ICS-DT-6 Control Instrument is under local mode, it shall not be controlled by PLC.

7.2.2流量与累计脉冲信号:Runoff and accumulated pulse signals

7.2.2.1 控制仪在“远控”状态下接受PLC 4-20mA流量控制信号,对应0-LC.(秤的额定流量)。When the control instrument is under “Remote” mode, it is controlled by PLC 4-20mA runoff control signal, in corresponding to 0-LC. (the rated runoff of the weigher).

7.2.2.2 控制仪输出4-20mA流量信号,对应流量0-LC.(秤的额定流量)。The control instrument outputs 4-20mA runoff signal, in corresponding to 0-LC. (the rated runoff of the weigher).

7.2.2.3小金棋牌 控制仪输出累计量脉冲,脉冲宽度100毫秒(继电器输出),每个脉冲所表示的累计量值可设定为0.001t-10t(由二级菜单中的设定 )。The control instrument outputs accumulated pulse signal, the pulse width is 1ooms (relay output), and each pulse indicates an accumulated ration, which may be set between 0.1—10t (set From the Class II menu in PEr. ).

7.3 控制仪机箱接线端子表The wiring terminals of the control instrument on the case

7.3.1端子示意图 Sketch of terminals

 


小金棋牌  

7.3.2端子定义Definition of terminals

机箱的后面有一排接线端子,分别为3芯、8芯、12芯、10芯、6芯接线端子,每个端子都有相应的符号表示。这些接线端子可能有外部强电信号接入,应注意不要接错或插错,否则有损坏控制仪的危险!There is a row of wiring terminals on the rear case of the instrument, namely 3-core, 8-core, 12-core, 10-core, 6-core wiring terminals; and each terminal is indicated with respective sign. There may have exterior power input, mention connect correctly, or there lies the danger of damaging the instrument!

7.3.3端子符号定义Definition of the terminal sign

A.3芯端子3-core Terminal

※——电源地线Power Ground  N——电源零线Power Neutral   L——电源相线Power Live

B. 8芯端子8-core Terminal

小金棋牌       OUT1+——累计量脉冲输出+Accumulated pulse output+      OUT1-——累计量脉冲输出- Accumulated pulse output-

小金棋牌       OUT2+——运行信号输出+Run signal output +        OUT2-——运行信号输出- Run signal output -

      OUT3+——故障信号输出+ Failure signal output +       OUT3-——故障信号输出- Failure signal output_

      OUT4+——备妥信号输出+ Ready signal output +       OUT4-——备妥信号输出- Ready signal output -

     上述4组输出均为继电器输出The abovementioned 4 groups are all of passive output from relays

C. 12芯端子12-core Terminal

IN1+——变频器故障+FC Failure +       IN1-——变频器故障- FC Failure-

IN2+——远程/本地+Remote/Local +          IN2-——远程/本地- Remote/Local-

IN3+——远程启动/停止+Remote Start/Stop+    IN3-——远程启动/停止- Remote Start/Stop-

IN4+——本地联锁+Local Interlock+          IN4-——本地联锁- Local Interlock-

上述4组输入均为无源开关量输入The abovementioned 4 groups are all of passive output from switches

 

Yd+——远控流量给定+ Remote runoff assignment+       Yd-+——远控流量给定- Remote runoff assignment-

LL+——流量信号输出+ Runoff signal output +       LL-——流量信号输出- Runoff signal output -

D。 10芯端子 10-core Terminal

BV+——传感器电源+ Power for transducer+          BV-——传感器电源- Power for transducer-

Sg+——传感器信号+Signal from transducer+           Sg-——传感器信号- Signal from transducer-

SV1+——测速电源+Power for speed detection+    SV1--——测速电源- Power for speed detection-    SP1+——测速信号+Speed detection signal+

SV2+——保留Save      SV2--——保留Save       SP2+——保留Save

E。 6芯端子6-core Terminal

VBP+——变频器控制+FC control +           VBP--——变频器控制-FC control -

VSP+——电压测速信号+   Signal of voltage for speed detection+     VSP-——电压测速信号- Signal of voltage for speed detection-

小金棋牌 RS485+——RS485通讯+     RS485 communication +      RS485-——RS485通讯- RS485 communication-

 

注Note:对于脉冲速度信号(霍尔传感器)采用SV1+SV1-SP1接法,二级菜单中Pcu 设置为期 0For pulse speed signal (Hall transducer), use wiring method of SV1+, SV1-, SP1; the setting of Pcu in Class II Menu shall be 0;

对于电压速度信号(如变频器电压反馈010V),采用VSP+VSP-接法,二级菜单中Pcu 设置为期 1.For voltage speed signal (such as FC feedback voltage 0—10V), use wiring method of VSP+, VSP-; the setting of Pcu in Class II Menu shall be 1.

小金棋牌  

 

235棋牌 小金棋牌下载 秒速时时彩计划 秒速时时彩 秒速时时彩开奖 极速3D彩票开奖 秒速时时彩计划 秒速时时彩开奖 秒速时时彩平台 秒速时时彩